Skip to content

Double-Leaf Fire Door with Panic Bars

A two-leaf fire door for wide passages and crowd evacuation.

Color
Red; RAL of your choice
Opening type
Double leaf
Style
Minimal
SM-YK003 red double-leaf fire door with panic bars on both leaves and vertical bolts on the passive leaf

01Model

What is this model for?

For places where a single leaf is not enough: a parking garage entrance, a loading corridor, a sports hall or a meeting hall exit. With a two-leaf fire door, the hard part is not opening it but closing it correctly. The leaves overlap; if they close in the wrong order, one catches on the other, and the door looks closed while a gap remains between the leaves. That is why in this model the door coordinator is an integral part of the job: it first waits for the passive leaf to close, then releases the active leaf. On the passive leaf, the panic bar is linked to vertical rods — pushing on the bar withdraws the top and bottom bolts and frees the leaf. Both leaves open in the direction of escape and each has a panic bar; a crowd can use both leaves at once. The clear passage width is measured after the coordinator and closers have been fitted; the leaf size on paper and the width a person can actually fit through are not the same.

Materials used

  • Steel frame and two leaves
  • Fire-resistant leaf core
  • Door coordinator
  • Panic bar with vertical rods

Profile sections and infill divisions are engineered according to the opening width, wind load and type of use; the values listed here are not a fixed commitment.

02Technical

Technical specifications

Since every piece is made to measure, dimensions are not standard; the fields in the table show which points are finalized during the site survey.

LeafDouble leaf, both open in the direction of escape
Escape hardwarePanic bar on each leaf; with vertical rods on the passive leaf
ClosingTwo door closers + door coordinator
Fire ratingSelected for the class required by the fire safety design
UseParking garage entrance, loading corridor, crowd evacuation
SizeClear passage measured after the hardware is fitted

03An honest note

When is this model not the right choice?

Where the width of a single leaf is enough for evacuation, a double leaf is both more expensive and needs more maintenance because of the coordinator and the second closer. If there is no space in front of the door for the swing arc of both leaves, it cannot be installed either; in that case, unequal (asymmetric) leaves are considered.

Selling the wrong model does nobody any good. Send us the measurements and a photo of the installation site; if this model does not fit, we will tell you which one does.

04Matching set

Models used together at the same entrance

Because the driveway gate, pedestrian gate and railing stand side by side at the same entrance, they are made with the same profile thickness and the same surface finish.

Send measurements for SM-YK003

The width and height of the opening, the ground conditions and, if you have one, a photo of the installation site are enough. If a site survey is needed, we will let you know.